Fuses That Provide Protection in Compliance With § 75.1910 (a), (b), (c), (d), (e), and (f) |
Available Circuit Interrupters
Nuisance Tripping and Trouble Shooting Guide
1. - A single battery system on the Cummins engine is very prone to nuisance tripping. The two battery system yields better performance.
2 - Caution - Only the circuit breakers and fuses listed have been evaluated for operation with the listed engine and battery system. The time-current curve for each application must be examined. Circuit breakers or fuses cross-referenced to replacement brands may not meet the requirements of 30CFR 75.1910(a), 75.1910(b), 75.1910(c), 75.1910(d), 75.1910(e), and 75.1910(f).
3 – AIRPAX and Carlingswitch circuit breakers are distributed by Generator Starter Service, P.O. Box 155, 50 East Center, Aurora, UT 84620. Phone (435) 529-7875.
4 - Carlingswitch circuit breakers are distributed by Alpha Services, Inc., P. O. Box 1045, Marion, IL 62959. Phone (618) 997-9999.
Nuisance Tripping and Trouble Shooting Guide
Ford |
Approval Number |
|
Fuses |
Circuit
Breakers |
|
AIRPAX |
Carlingswitch |
||||
7.3L DIT NAVISTAR |
7E-B067 7E-B068 7E-B069 |
12 Volt; 2-Parallel
825CCA HD Batteries in Two Trays, One On Each Side of Engine, No. 1 AWG
Cables |
In Each Bussmann FRS-R-100 Ferraz Shawmut TRS-100RDC Littelfuse FLSR-80A |
In Each 209-130547-4-V |
In Each FA1-X0-09-675-32A-BG |
545D, New |
UNK |
12 Volt; One 1300CCA 8D |
Bussmann FRS-R-150 Ferraz Shawmut TRS-150RDC Littelfuse FLSR-150A |
JLE-1-30453-2 |
FA1-X0-09-644-32A-BG |
Bussmann = Cooper Bussmann,
Inc. Littelfuse
= Littelfuse, Inc. Ferraz Shawmut = Gould Shawmut
1. - A single battery system on the Cummins engine is very prone to nuisance tripping. The two battery system yields better performance.
2 - Caution - Only the circuit breakers and fuses listed have been evaluated for operation with the listed engine and battery system. The time-current curve for each application must be examined. Circuit breakers or fuses cross-referenced to replacement brands may not meet the requirements of 30CFR 75.1910(a), 75.1910(b), 75.1910(c), 75.1910(d), 75.1910(e), and 75.1910(f).
3 – AIRPAX and Carlingswitch circuit breakers are distributed by Generator Starter Service, P.O. Box 155, 50 East Center, Aurora, UT 84620. Phone (435) 529-7875.
4 - Carlingswitch circuit breakers are distributed by Alpha Services, Inc., P. O. Box 1045, Marion, IL 62959. Phone (618) 997-9999.