Fuses That Provide Protection in Compliance With
§ 75.1910 (a), (b), (c), (d), (e), and (f)




Caterpillar

 

 

Caterpillar

Approval

Number

 

Battery System

 

Fuses

Circuit Breakers

AIRPAX

Carlingswitch

3304 PCNA

7E-A003

7E-B004

12 Volt; 2-Parallel 1155CCA Batteries in One Tray, 1/0 AWG Cables

Bussmann FRS-R-150

Ferraz Shawmut TRS-150RDC

Littelfuse FLSR-150A

JLE-1-30453-2

FA1-X0-09-644-32A-BG

3304 PCNA

7E-A003

7E-B004

24 Volt; 2-Series 1155CCA Batteries in One Tray, 1/0 AWG Cables

Bussmann FRS-R-125

Ferraz Shawmut TRS-125RDC

Littelfuse FLSR-125A

JLE-1-30453-1

FA1-X0-09-645-32A-BG

3306 PCNA

7E-A002

7E-B003

24 Volt; 2-Series 1155CCA Batteries in One Tray, 1/0 AWG Cables

Bussmann FRS-R-150

Ferraz Shawmut TRS-150RDC

Littelfuse FLSR-150A

JLE-1-30453-2

FA1-X0-09-644-32A-BG

3306 DITA

7E-B010

12 Volt; 2-Parallel 1300CCA Batteries in One Tray, 1/0 AWG Cables

Bussmann FRS-R-175

Ferraz Shawmut TRS-175RDC

Littelfuse FLSR-175A

JLE-1-30453-3

FA1-X0-09-673-32A-BG

3306 DITA

7E-B010

24 Volt; 2-Series 1300CCA Batteries in One Tray, 1/0 AWG Cables

Bussmann FRS-R-175

Ferraz Shawmut TRS-175RDC

Littelfuse FLSR-175A

JLE-1-30453-3

FA1-X0-09-673-32A-BG

3406E ATTA

7E-B018

24 Volt; 2-Series 4D 1000CCA Batteries in One Tray, 1/0 AWG Cables

Bussmann FRS-R-200

Ferraz Shawmut TRS-200RDC

Littelfuse FLSR-200A

JLE-1-30453-4

FA1-X0-09-674-32A-BG

3056 PCNA

7E- B066

12 Volt; One HD 1000CCA Battery, 1/0 AWG Cables

Bussmann FRS-R-125

Ferraz Shawmut TRS-125RDC

Littelfuse FLSR-125A

JLE-1-30453-1

FA1-X0-09-645-32A-BG

3056 PCNA

7E- B066

24 Volt; 2 Series HD 1000CCA Batteries in One Tray, 1/0 AWG Cables

Bussmann FRS-R-100

Ferraz Shawmut TRS-100RDC

Littelfuse FLSR-100A

209-130547-4-V

FA1-X0-09-675-32A-BG

Notes:

1. - A single battery system on the Cummins engine is very prone to nuisance tripping. The two battery system yields better performance.

2 - Caution - Only the circuit breakers and fuses listed have been evaluated for operation with the listed engine and battery system. The time-current curve for each application must be examined. Circuit breakers or fuses cross-referenced to replacement brands may not meet the requirements of 30CFR 75.1910(a), 75.1910(b), 75.1910(c), 75.1910(d), 75.1910(e), and 75.1910(f).

3 – AIRPAX and Carlingswitch circuit breakers are distributed by Generator Starter Service, P.O. Box 155, 50 East Center, Aurora, UT 84620. Phone (435) 529-7875.

4 - Carlingswitch circuit breakers are distributed by Alpha Services, Inc., P. O. Box 1045, Marion, IL 62959. Phone (618) 997-9999.