MSHA - Directorate of Technical Support A Troubleshooting Guide for
Roof Support Systems


Appendix E

E.1 BAIL/SUPPORT NUT TOO STRONG

If the Bail/support nuts are too strong the support will not tension properly in certain situations. The primary function of the bail/support nut is to hold the shel of an expansion anchor in place until the plug begins to expand it into the borehole wall. Once this occurs the bail/support nut is no longer necessary and should break away. If the bail/support nut does not break away it will prevent the bolt from being drawn up through the plug as it is rotated. With a support nut this will cause most of the tension to occur between the plug and the support nut. When this situation occurs the result can be high installed torque with low tension, erratic tension, springy bolt, the anchor breaks on installation, or the bolt breaks on installation. Check bail/support nut using procedure listed in section A.5. The breaking torque of the bail/support nut should not exceed the installed torque of the support system.

E.2 BOLT INSERTION TOO FAST

Often time when bolts bend on installation or when spinners are prevalent the cause is due to the operator inserting the bolt too fast. Certain expansion anchors offer more resistance than others when pushing through a grout cartridge and some grouts offer more resistance than others. In either case the more rapid the bolt insertion the greater the forces applied to the expansion anchor and bolt. In some cases the bail/support nut can break and the expansion shell will become dislodged from the plug resulting in a spinner. When long bolts are used the result can be that the bolt bends before it is fully inserted in the borehole. If any of the above problems are occurring instruct the operator to slow down the bolt insertion. If that does not alleviate the problem then consider changing the grout, the expansion anchor or using a stronger bail/support nut.

E.3 GROUT LUBRICATING BOREHOLE

In this situation the grout acts as a lubricant and prevents the shell from anchoring in the borehole wall. Because the shell cannot get a "bite" in the hole the entire unit just spins on the bolt until it runs out of threads. A stronger bail/support nut could help by holding the shell in place long enough for the plug to expand the shell, which would allow the serrations to cut through the grout, and contact the borehole wall. If the bail/support nut is too strong other problems can be encountered (see E.1 ). Sometimes pre-expanding the anchors will eliminate the problem, however, pre-expanding the anchors too much can interfere with the grout flow around the anchor, causing the bolt to bend on insertion.

E.4 GROUT CARTRIDGE MATERIAL INTERFERES WITH ANCHOR PERFORMANCE

This condition is very difficult to detect. If after using grout from a different lot or manufacturer you start encountering spinners or tension/torque problems the grout cartridge could be responsible. If you suspect that the grout cartridge contact both the grout manufacturer and the bolt manufacturer.

E.5 ANCHOR DESIGN

Not all expansion anchors are suitable for use with grout. Many of the older expansion anchors were not designed for use with grout. Anchors specifically designed to be used with grout are available from all manufacturers. These anchors have more streamlined shapes and often have passages in them to allow the grout to flow more smoothly.