Slide (43 of 85)
|
|
5. The engine shuts down when the stop button located on the instrument panel is held in.
6. The plugs sealing the intake vacuum and exhaust back pressure test ports are securely installed.
7. Test for proper scrubber low water shutdown. Perform the test described in the equipment manufacturer’s power package permissibility checklist.
WARNING: SCRUBBER WATER MAY BE HOT!
8. After engine has automatically shut down due to low water, try restarting the engine prior to replenishing the water. The engine may turn over but must not start. Replenish scrubber water.
|
|